Aljzat
G-40
The G-40 base is designed for mounting 40, 4043 and 4046 model range detectors (e.g. DOR-40, DUR-4043) on a ceiling and for connecting detection lines to them. The base can be mounted in a PG-40 base attachment installed on suspension strands or in rooms where water vapour condensation is present on the ceiling. The base is equipped with an additional PG-7 sealing gland; this enables for it to become a suspended base.
Moreover, a special P-40 masking ring can be assembled in order to mask visible parts of the detector base (e.g. in offices, etc.). The P-40 device is not included in the order product package – and it should be ordered separately.
Moreover, a special P-40 masking ring can be assembled in order to mask visible parts of the detector base (e.g. in offices, etc.). The P-40 device is not included in the order product package – and it should be ordered separately.
Aljzat kiegészítés (G40 Aljzathoz)
PG-40
The G-40 base is designed for mounting 40, 4043 and 4046 model range detectors (e.g. DOR-40, DUR-4043) on a ceiling and for connecting detection lines to them. The base can be mounted in a PG-40 base attachment installed on suspension strands or in rooms where water vapour condensation is present on the ceiling. The base is equipped with an additional PG-7 sealing gland; this enables for it to become a suspended base.
Moreover, a special P-40 masking ring can be assembled in order to mask visible parts of the detector base (e.g. in offices, etc.). The P-40 device is not included in the order product package – and it should be ordered separately.
Moreover, a special P-40 masking ring can be assembled in order to mask visible parts of the detector base (e.g. in offices, etc.). The P-40 device is not included in the order product package – and it should be ordered separately.
Aljzat PUO-35(Ex) Érzékelőhöz
G-33
The G-33 base is designed to connect fire detectors into fire detection and alarm systems. It is suitable for usage together with PUO-35Ex intrinsically safe detectors.
Beam Smoke Detector (for various systems)
DOP-6001R
The DOP-6001R beam smoke detector is designed for smoke detection at the onset of a fire combustion stage. It is especially suited for protection of indoor spaces, in which the appearance of smoke is likely during ignition of a fire and where, due to a large space area, installation of a greater number of point smoke detectors would be necessary.
The DOP-6001R beam smoke detectors are equipped with fire alarm and fault relay outputs, which enable them to operate in detection lines of any fire alarm system control panels as well as in burglar alarm systems.
The DOP-6001R beam smoke detectors are equipped with fire alarm and fault relay outputs, which enable them to operate in detection lines of any fire alarm system control panels as well as in burglar alarm systems.
Címezhető Vonali Füstérzékelő
DOP-6001
The DOP-6001 beam smoke detector is designed for smoke detection at the start of a fire. It is especially suitable for protection of indoor spaces, in which the appearance of smoke is likely during ignition of a fire, and where, due to a large space area, installation of a greater number of point smoke detectors would be necessary.
These detectors can operate exclusively in POLON-ALFA manufactured fire alarm system detection lines: directly in addressable loop-shaped lines of the POLON 4000 system, in the IGNIS 1000/2000 system conventional lines.
These detectors can operate exclusively in POLON-ALFA manufactured fire alarm system detection lines: directly in addressable loop-shaped lines of the POLON 4000 system, in the IGNIS 1000/2000 system conventional lines.
Fix hőmérséklet/hősebesség érzékelő
TUP-40
The TUP-40 fixed temperature/rate-of-rise heat (temperature) detector is designed to detect a fire hazard in indoor premises, in which during the initial phase of a fire excessive or very fast rise of temperature can be observed, and where, due to existing conditions, installation of smoke detectors is not possible.
The TUP-40 fixed temperature/rate-of-rise heat detector reacts to a rise in temperature occurring during a fire. The detector works as a fixed temperature detector when temperature excesses the threshold pursuant to a given class, and as a rate-of-rise detector during a sudden rise in temperature.
The TUP-40 fixed temperature/rate-of-rise heat detector reacts to a rise in temperature occurring during a fire. The detector works as a fixed temperature detector when temperature excesses the threshold pursuant to a given class, and as a rate-of-rise detector during a sudden rise in temperature.
Gyújtószikramentes Hőérzékelő
TUN-38Ex
The TUN-38Ex heat (temperature) detector is designed to detect a fire hazard in rooms, where during the first phase of a fire a rapid rise of temperature may occur, or where temperature may exceed a defined danger level.
The TUN-38Ex is a universal heat detector, which can be programmed to operate as a fixed temperature or fixed/rate-of-rise heat detector. It is also possible to change the class of these detectors adapting them to specific applications.
The TUN-38Ex is a universal heat detector, which can be programmed to operate as a fixed temperature or fixed/rate-of-rise heat detector. It is also possible to change the class of these detectors adapting them to specific applications.
Gyújtószikramentes Láng Érzékelő
PUO-35Ex
The PUO-35, PUO-35Ex flame detectors are designed for detection and signalisation of a flame ignition in case of a fire hazard.
The PUO-35Ex flame detector is intrinsically safe (Ex) to be used in explosion hazard areas. It operates in detection lines connected to POLON-ALFA fire alarm system control panels with an appropriate intrinsically safe separator.
The PUO-35Ex flame detector is intrinsically safe (Ex) to be used in explosion hazard areas. It operates in detection lines connected to POLON-ALFA fire alarm system control panels with an appropriate intrinsically safe separator.
Gyújtószikramentes Univerzális, Optikai, Füstérzékelő
DUR-40Ex
The DUR-40Ex optical smoke detector is designed for detection of a visible smoke at a start of a fire's flameless stage
when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature. The DUR-40Ex is an intrinsically safe detector designed for installation in explosion hazard zones.
when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature. The DUR-40Ex is an intrinsically safe detector designed for installation in explosion hazard zones.
Home smoke detector
ADR-20N
The residential ADR-20N smoke detector is designed to detect visible smoke at a start of a fire’s flameless stage when material starts to smoulder, and therefore, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
It enables early detection of a fire in small residential facilities such as apartments, houses (in cellars, garages, attics, etc.).
It enables early detection of a fire in small residential facilities such as apartments, houses (in cellars, garages, attics, etc.).
Home smoke detector
ADR-20R
The ADR-20R optical smoke detector is designed for detection of visible smoke at a start of a fire’s flameless stage when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
The ADR-20R detector is intended to interoperate with detector lines of any burglar alarm system control panels. It is equipped with relay output.
The ADR-20R detector is intended to interoperate with detector lines of any burglar alarm system control panels. It is equipped with relay output.
Láng Érzékelő UV
PUO-35
The PUO-35, PUO-35Ex flame detectors are designed for detection and signalisation of a flame ignition in case of a fire hazard.
The PUO-35Ex flame detector is intrinsically safe (Ex) to be used in explosion hazard areas. It operates in detection lines connected to POLON-ALFA fire alarm system control panels with an appropriate intrinsically safe separator.
The PUO-35Ex flame detector is intrinsically safe (Ex) to be used in explosion hazard areas. It operates in detection lines connected to POLON-ALFA fire alarm system control panels with an appropriate intrinsically safe separator.
Maszkoló gyűrű (for G-40 Aljzathoz)
P-40
Multi-band Láng Érzékelő (coming soon)
PPW-40REx
Más gyártók rendszereihez.
Multi-szenzor Érzékelő (Hő és Láng Érzékelő)
TOP-40
The multi-detector TOP-40 heat and flame detector is designed to detect and signal a source of a fire in areas where there is a rise of temperature and a visible flame.
Application of two sensors: heat and infrared radiation (IR) makes the detector more resistant to disturbances and minimizes possible initiation of false alarms and enables this detector to be used in premises where a lot of dust appears.
Application of two sensors: heat and infrared radiation (IR) makes the detector more resistant to disturbances and minimizes possible initiation of false alarms and enables this detector to be used in premises where a lot of dust appears.
Multi-szenzor Érzékelő (Optikai füst és Hőérzékelő)
DOT-4046
The DOT-4046 processor based two-sensor detector is designed for detection of a smoke and a rise in temperature, concurrent with a fire at its early development stage. The detector has two built-in sensors: smoke and heat. This allows the use of the detectors in closed spaces where in case of fire there is a visible smoke or a rise in temperature or where both of these factors appear simultaneously.
The DOT-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 system fire alarm panels.
The DOT-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 system fire alarm panels.
Multi-szenzor Érzékelő (Optikai füst és Hőérzékelő)
DOT-40
The DOT-40 multi-sensor (optical smoke and heat) detector is designed for detection of a smoke and a rise in temperature concurrent with a fire at its early development stage. The detector has two built-in sensors: smoke and heat. This allows for the use of the detectors in closed spaces where in case of a fire there is a visible smoke or a rise in temperature or where both of these factors appear simultaneously.
The applied microprocessor element and the appropriate detector software guarantee, that the entire phenomenon accompanying a fire within the vicinity of the detector will quickly be analysed and possible false alarms will be eliminated.
The applied microprocessor element and the appropriate detector software guarantee, that the entire phenomenon accompanying a fire within the vicinity of the detector will quickly be analysed and possible false alarms will be eliminated.
Multi-szenzor Érzékelő (Optikai füst és Láng Érzékelő)
DPR-4046
The DPR-4046 microprocessor based multi-sensor detector is designed for detection of a visible smoke and a flame, concurrent with an early stage of an open fire ignition. The detector has two types of built-in sensors (smoke and flame). It enables detection of a fire at its beginning stage that is when material starts to smoulder, accompanied by a visible smoke or a rise in temperature or when both these physical phenomena are present.
The DPR-4046 detector can operate in lines/loops of all addressable POLON 4000 system fire alarm panels.
The DPR-4046 detector can operate in lines/loops of all addressable POLON 4000 system fire alarm panels.
Multi-szenzor multi-állapot Érzékelő (füst és hő)
DUT-6046
The DUT-6046 microprocessor based multi-sensor smoke and heat detector is designed to detect a visible smoke and a rise in temperature, which are indicative of an early stage of an open fire ignition. This detector is characterized by a significant resistance to air velocity and changes in air pressure. The application of a double smoke detecting systems (IR and UV) as well as a double heat detecting systems ensures increased resistance to false alarms, caused by e.g., water vapour and dust inside the measuring chamber, while maintaining small dimensions and high aesthetics of the product.
The DUT-6046 detectors can operate in lines/loops of all addressable POLON 4000 system fire alarm panels.
The DUT-6046 detectors can operate in lines/loops of all addressable POLON 4000 system fire alarm panels.
Optikai (photoelectric) Füstérzékelő
DOR-40
The DOR-40 optical smoke detector is designed for detection of a visible smoke, concomitant with most fires. It enables detection of fire prior to its ignition, when material starts to smoulder, and therefore, a long time before the appearanceof an open flame and a noticeable rise in temperature.
The DOR-40 is a Tyndall effect based optical smoke detector. Its operation is based on measuring infrared (IR) light scattered by smoke particles (aerosol) entering the measuring chamber which is inaccessible to external light.
The DOR-40 is a Tyndall effect based optical smoke detector. Its operation is based on measuring infrared (IR) light scattered by smoke particles (aerosol) entering the measuring chamber which is inaccessible to external light.
Optikai Füstérzékelő
DOR-4043
The DOR-4043 processor based optical smoke detector is designed for detection of a visible smoke, at a start of a fire’s flameless stage when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
The DOR-4043 optical smoke detector can operate only in lines/ loops of the POLON 4100 and POLON 4200 addressable fire alarm systems.
The DOR-4043 optical smoke detector can operate only in lines/ loops of the POLON 4100 and POLON 4200 addressable fire alarm systems.
Optikai Füstérzékelő
DOR-4046
The DOR-4046 processor based optical smoke detector is designed to detect a visible smoke at a start of a fire’s flameless stage when material starts to smoulder, and therefore, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
The DOR-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 fire alarm system Panels.
The DOR-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 fire alarm system Panels.
Prizmatükör (DOP-40, DOP-40R)
E39-R8
The E39-R8 prism reflector and the 4xE39-R8 prism reflector panel are designed to operate together with the DOP-6001R and DOP-6001 beam smoke detectors.
Tükörcsomag (DOP-40 és DOP-40R)
4xE39-R8
The E39-R8 prism reflector and the 4xE39-R8 prism reflector panel are designed to operate together with the DOP-6001R and DOP-6001 beam smoke detectors.
Univerzális Füstérzékelő
DUR-4046
The DUR-4046 processor based optical smoke detector is designed for detection of a visible smoke accompanying an early stage of an open fire ignition. It enables detection of a fire at its beginning stage when material starts to smoulder, therefore a long time prior to the appearance of an open flame and a noticeable rise in temperature.
The DUR-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 system fire alarm panel.
The DUR-4046 optical smoke detector can operate only in lines/loops of all addressable POLON 4000 system fire alarm panel.
Univerzális Hőérzékelő
TUN-4043
The TUN-4043 universal microprocessor based heat (temperature) detector is designed to detect fire hazard in premises, in which a rapid rise in temperature may occur during the initial phase of a fire or where temperature may exceed a predefined danger level.
The TUN-4043 heat detector is universal. It can be programmed (from the control panel level) to a specified operation mode and operates as a fixed or fixed/rate-of-rise heat detector.
The TUN-4043 heat detector is universal. It can be programmed (from the control panel level) to a specified operation mode and operates as a fixed or fixed/rate-of-rise heat detector.
Univerzális Hőérzékelő
TUN-4046
The TUN-4046 universal addressable multi-state microprocessor based heat (temperature) detector is designed to detect a fire hazard in indoor premises where during an initial stage of a fire a rapid rise of temperature may occur or the temperature may exceed a pre-set danger level.
The TUN-4046 heat detector is universal. It can be programmed from the control panel level to operate as a fixed or fixed/ rate-of-rise heat detector.
The TUN-4046 heat detector is universal. It can be programmed from the control panel level to operate as a fixed or fixed/ rate-of-rise heat detector.
Univerzális, Optikai Füstérzékelő
DUR-4043
The DUR-4043 microprocessor based universal optical smoke detector is designed for detection of a visible smoke at thestart of a fire’s flameless stage when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
The optical smoke detector DUR-4043 can operate only in lines/loops of the POLON 4100 and POLON 4200 addressable fire alarm systems.
The optical smoke detector DUR-4043 can operate only in lines/loops of the POLON 4100 and POLON 4200 addressable fire alarm systems.
Univerzális, Optikai Füstérzékelő
DUR-40
The DUR-40 universal optical smoke detector is designed for detection of a visible smoke at the start of a fire’s flameless stage when material starts to smoulder, and therefore generally, a long time prior to the appearance of an open flame and a noticeable rise in temperature.
Its operation is based on measuring the infrared (IR) radiation scattered by smoke particles.
Its operation is based on measuring the infrared (IR) radiation scattered by smoke particles.
Vezetéknélküli Érzékelő adapter
ACR-4001
The ZCR-4001 wireless radio detector set is designed for early detection of a fire in premises, where wiring connection of the detectors and the control panel is not possible. The above wireless set contains at least one universal wireless smoke detector - DUR-4047 and the ACR-4001 radio detector adapter, which can work with up to 16 wireless radio detectors.
The DUR-4047 processor based wireless radio optical smoke detector is designed for detection of a visible smoke, concurrent with an early stage of an open fire ignition that is when material begins to smoulder, i.e. a long time before the appearance of an open flame and a rise in temperature.
The DUR-4047 processor based wireless radio optical smoke detector is designed for detection of a visible smoke, concurrent with an early stage of an open fire ignition that is when material begins to smoulder, i.e. a long time before the appearance of an open flame and a rise in temperature.
Vezetéknélküli radió vezérlésű Optikai Füstérzékelő
DUR-4047
ACR-4001-el működik.